ACD10 CO2 sensor Linux driver

 

ACD10 CO2 gas sensor driver - serdev in IIO subsystem. 

0) Enable 5V power supply on am62x board on 40 pin user expansion header. 

# 1. Ensure P06 is set HIGH in the output register (0x04) # 0xff | 0x40 remains 0xff since all outputs are already high 


$ i2cset -f -y 1 0x22 0x04 0xff 

 # 2. Configure P06 as an output by clearing bit 6 (0x40) in the config register (0x0C) # 0xf7 & 0xbf clears bit 6 -> results in 0xb7 (0b10110111) 

$ i2cset -f -y 1 0x22 0x0c 0xb7

This needs to be done on every boot.

1) Device tree on am62x - pinmux and uart device nodes

2) serdev framework


3) UART 5v to 3.3 volt conversion for pin compatibility. 

tx from am62x --> 3.3v --> let it go directly to sensor. 

rx from am62x --> step down tx of sensor. 

No comments: